客服热线:1352-4434-134

赛德斯威技术服务(深圳)有限公司 企业资料通过认证

认证检测技术支持

普通会员

赛德斯威技术服务(深圳)有限公司

普通会员

  • 企业类型:

    个体经营 ()

  • 经营模式:

  • 荣誉认证:

       企业资料通过认证

  • 保  证  金:

    已缴纳 0.00

  • 注册年份:

    2016

  • 主     营:

    认证检测技术支持

  • 地     址:

    深圳市福田区华强北街道华强北路4005号海馨苑1号楼1902

您当前的位置:首页 » 产品检测 » ASTMF3340 Sleeping Bag R test
ASTMF3340 Sleeping Bag R test
点击图片查看原图
产品: 浏览次数:286ASTMF3340 Sleeping Bag R test 
品牌: 塞德斯威
R值: 测试
单价: 100.00元/R值
最小起订量:
供货总量:
发货期限: 自买家付款之日起 3 天内发货
有效期至: 长期有效
最后更新: 2024-04-21 17:02
 
询价
详细信息

ASTM F3340 Camping Mattress and Sleeping Bag R-value testing

 

Standard

ASTM F3340 Standard Test Method for Thermal Resistance of Camping Mattresses Using a Guarded Hot Plate Apparatus

 

What is R-value in ASTM F3340

R-value, as used in technical terms, is a measurement of thermal resistance; the greater the R-value, the more thermally resistant the material or structure is. Customers can use this figure to compare the warmth of various pads with a clear-cut assessment. They will be able to find the ideal sleeping pad as a result.

 

Why Does the R-value of a Camping Mattress/Sleeping Pad Matter?

Due to conductive heat loss between your warm body and the cold ground, if you were to roll out your sleeping bag and lay down on the ground, you would immediately become cold. A layer of insulation would not form between the two thanks to the compressed down. By choosing a sleeping pad with the right amount of insulation, you can keep warm all night long and wake up ready to tackle the path. This procedure explains why a sleeping mat is crucial.

 

How to test R-value

based on ASTM F3340, there is a sleeping mat sandwiched between two metal plates inside this thermally enclosed container. A hot plate (35 degrees Celsius) on top, which simulates the body, and a cold plate (5 degrees Celsius), which simulates the ground, are sandwiched between pads in this test. Testers track how much energy the top plate requires to maintain a constant temperature of 35 degrees over the course of four hours. The more insulative the pad, the less energy it requires. The less insulative the pad, the more energy it requires. An equation is used to calculate the R-value for each pad based on the energy needed to keep the temperature of the plate constant. The greater the R-value, the less power is needed to maintain the temperature of the plate.

SATISFY Tech & Service LLC provides the testing of R-value ASTM F3340, please contact SATISFY for further information of R-value ASTM F3340.


询价单 
0条  相关评论
在线客服

公司咨询电话

13163736831
18926762893
(9:30-17:30)

扫一扫进入公司官网移动站

扫一扫有惊喜